CONTROLLERS AND ANALYSERS – AW 96

CONTROLLERS AND ANALYSERS – AW 96

Controller for measurement and proportional control of pH, Redox, Chlorine and conductivity.

Description

Controller for measurement and proportional control of pH, Redox, Chlorine and conductivity.

AW 96 pH

• Controller for measurement and proportional control of pH, measure 0.00-14.00 pH;
• Microprocessor technology with digital control and LCD display;
• n.3 indipendent set-points, free contact relay output On-Off;
• 1 output relay selectable in proportional time-pause mode;
• Hysteresi and activation delay selectables;
• 4-20 mA output for recorder with galvanic isolation;
• 4-20 mA proportional output, selectable on set-point2, with galvanic insulation;
• Wall mounting box, IP65 protection degree;
• pH electrode not included;
• Standard power supply 230Vac.

AW 96 Rx

• Controller for measurement and proportional control of Redox potential over range 0-2000 mV;
• Microprocessor technology with digital control and LCD display;
• 3 set-points independently adjustable with On/Off volt free relay outputs;
• 1 pulse proportional volt free relay output;
• Hysteresis adjustment and programmable delay;
• 4-20 mA output for chart recording with galvanic isolation;
• 4-20 mAproportional output;
• Vertical mounting version IP65 enclosure;
• Redox electrode not included;
• Power supply as standard 230VAC.

AW 96 S Chlorine

• Controller for measurement and proportional control of free chlorine over range 0.00-10.00 ppm;
• Microprocessor technology with digital control and LCD display;
• 3 set-points independently adjustable with On/Off volt free relay outputs;
• 1 pulse proportional volt free relay output;
• Hysteresis adjustment and programmable delay;
• 4-20 mA output for chart recording with galvanic isolation;
• 4-20 mA proportional output;
• Vertical mounting version IP65 enclosure;
• Chlorine electrode not included (A-CG);
• Power supply as standard 230VAC.

AW 96 S CD

• Controller for measurement and proportional control of conductivity over range 0-20000μS;
• Other ranges on request are 0-2000μS or 0-200μS;
• Microprocessor technology with digital control and LCD display. 3 indipendent set-points, free contact relay output On-Off;
• 1 pulse proportional volt free relay output and 1 timed pulse proportional volt free relay output;
• Hysteresi and activation delay selectable;
• Manual and automatic temperature compensation 0-100°C;
• Temperature probe not included (compatible with A-ST1 probe);
• 4-20 mA output for recorder with galvanic isolation;
• 4-20 mA proportional output, selectable on set-point2, with galvanic insulation;
• Wall mounting box, IP65 protection degree;
• Conductivity electrode not included (compatible with A-CD probe with exclusion the termocompensate)
• Standard power supply 230VAC.

Model

CODE DESCRIPTION

ADW96PH AW-96 PH 230V

ADW96PHF AW-96 PHF 230V

ADW96RX AW-96 RX 230V

ADW96CL AW-96 CL 230V

ADW96CD AW-96 CD 0-20000 uS 230V

ADW96CD1 AW-96 CD 0-2000 uS 230V

ADW96CD2 AW-96 CD 0-200 uS 230V

INSTALLATION KIT

ADSP6020156 WALL FIXING BRACKET

ADSP6020224 WALL ADAPTERFIXING BRACKET 4 SCREW