CONTROLLERS AND ANALYSERS – ADIN20 START

CONTROLLERS AND ANALYSERS – ADIN20 START

Digital Controller DIN rail mounting.
• Backlighted LCD display, 2 lines x 16 characters and 4 keys keypad, for an easy user interface;
• 2 set-points with independent adjustment and free relay outputs, selectables in On-Off mode, Proportional or Time-Pause Mode;
• 0/4-20 mA Proportional Output with selectable range;
• PT100 temperature probe, Level and Flow sensor inputs;
• Setting menu protected by password;
• Fast setting by user menu selection, manual control of both relays (pumps priming), runtime monitoring of all outputs and control of the last probe calibration;
• Realy n.2 selectable as setpoint or on each alarm signal.
• Statistics of the alarms, of the number of setpoint activations and of the operating time of each relay;
• Self-calibration of measure probes.

Description

Digital Controller DIN rail mounting.
• Backlighted LCD display, 2 lines x 16 characters and 4 keys keypad, for an easy user interface;
• 2 set-points with independent adjustment and free relay outputs, selectables in On-Off mode, Proportional or Time-Pause Mode;
• 0/4-20 mA Proportional Output with selectable range;
• PT100 temperature probe, Level and Flow sensor inputs;
• Setting menu protected by password;
• Fast setting by user menu selection, manual control of both relays (pumps priming), runtime monitoring of all outputs and control of the last probe calibration;
• Realy n.2 selectable as setpoint or on each alarm signal.
• Statistics of the alarms, of the number of setpoint activations and of the operating time of each relay;
• Self-calibration of measure probes.

ADIN20S pH-Rx

• Controller for measurement and control of pH measure range 0.00-14.00 pH, with 0.01 pH accuracy, Redox potential, measure range -1500÷1500 mV, with 1 mV accuracy;
• Changing of the monitored parameter by Advanced Settings Menu, protected by password.

ADIN20S CHLORINE

• Controller for measurement and regulation of free chlorine available for amperometric Pt- Cu probes;
• Measure Range:0.00-10.00 ppm.

ADIN20S CD

• Controller for measurement and control of conductivity, available for conductivity probes with K=1, K=5 and K=10.

ADIN20S CL-J

• Controller for measurement and regulation of free chlorine and each other measure available for amperometric selective membrane 4-20mA probes;
• Measure Range selectable: 0.00-2.00 ppm/0.00-5.00ppm/0.00-10.00ppm/0.00-20.00ppm/0-200ppm.

Model

CODE DESCRIPTION

ADINS20PHRX AQUA DIN 20 START PH-RX CONTROLLER

ADINS20CL AQUA DIN 20 START CHLORINE (PT-CU) CONTROLLER

ADINS20CD AQUA DIN 20 START CONDUCTIVITY CONTROLLER

ADINS20CLJ AQUA DIN 20 START PPM A-J PROBES